FireCADCalc

Blowdown Heat Recovery (Flash Vessel and Cooler)

Heat recovered from continuous blowdown by a flash vessel and a drain cooler heating make-up water, with the make-up temperature rise and the share recovered.

Inputs

Examples: 0.5 t/h at 18 bar(a), flash 1.5 bar(a), drain 40 °C, make-up 5 t/h at 25 °C2 t/h at 45 bar(a), flash 2 bar(a), drain 35 °C, make-up 20 t/h at 30 °C

Blowdown

Usually the deaerator pressure, where the flash steam is used.

Make-up water

Results

The make-up water leaves hotter than the drain: the cooler must be counter-flow, and the approach at the hot end is tight.

Heat recovered545.07kW
Share of blowdown heat recovered98.504%
Make-up water outlet temperature36.162°C
Flash steam fraction28.046%
Flash steam flow560.93kg/h
Residual blowdown to the cooler1,439.1kg/h
Heat in the flash steam (above make-up temperature)402.02kW
Heat transferred in the drain cooler143.05kW
Heat in the blowdown (above make-up temperature)553.35kW
Flash vessel temperature120.21°C
Boiler water enthalpy1,122.1kJ/kg
Liquid enthalpy at flash pressure504.68kJ/kg
Flash steam enthalpy2,706.2kJ/kg
Drain enthalpy146.82kJ/kg

Download PDF Link to this result

Log in to save calculations to your dashboard.

Formula

Flash vessel (isenthalpic flash of saturated boiler water) and drain cooler:

\(x = \frac{h_{f,b} - h_{f,f}}{h_{g,f} - h_{f,f}} \qquad \dot m_{fs} = x\,B \qquad \dot m_l = (1-x)\,B\)

\(\dot Q_{fs} = \dot m_{fs}\,(h_{g,f} - h_{mu}) \qquad \dot Q_{hx} = \dot m_l\,(h_{f,f} - h_d) \qquad \dot Q_{rec} = \dot Q_{fs} + \dot Q_{hx}\)

\(\dot Q_{bd} = B\,(h_{f,b} - h_{mu}) \qquad \eta_{rec} = \frac{\dot Q_{rec}}{\dot Q_{bd}} \qquad h_{mu,2} = h_{mu} + \frac{\dot Q_{hx}}{\dot m_{mu}}\)

Variables

Symbol Meaning SI unit
\(B\) blowdown flow kg/s
\(p_b\) boiler drum absolute pressure Pa
\(p_f\) flash vessel absolute pressure Pa
\(T_d\) drain temperature leaving the cooler K
\(\dot m_{mu}\) make-up water flow through the cooler kg/s
\(T_{mu}\) make-up water inlet temperature K
\(p_{mu}\) make-up water absolute pressure Pa
\(x\) flash steam fraction –
\(\dot m_{fs}\) flash steam flow kg/s
\(\dot m_l\) residual blowdown to the cooler kg/s
\(\dot Q_{fs}\) heat in the flash steam above make-up temperature W
\(\dot Q_{hx}\) heat transferred in the drain cooler W
\(\dot Q_{rec}\) heat recovered W
\(\dot Q_{bd}\) heat in the blowdown above make-up temperature W
\(\eta_{rec}\) share of blowdown heat recovered –
\(T_{mu,2}\) make-up water outlet temperature (from \(h_{mu,2}\)) K
\(T_f\) flash vessel saturation temperature K
\(h_{f,b}\) saturated liquid enthalpy at drum pressure J/kg
\(h_{f,f}\) saturated liquid enthalpy at flash pressure J/kg
\(h_{g,f}\) saturated vapour enthalpy at flash pressure J/kg
\(h_d\) drain enthalpy J/kg
\(h_{mu}\) make-up water inlet enthalpy J/kg

Method and standards

Energy balances on the flash vessel and the drain cooler with enthalpies from FireCAD's IAPWS-IF97 implementation. The make-up outlet temperature is found from its pressure and enthalpy (IF97 backward equation, refined on the forward equation).

Assumptions and limits

  • Saturated blowdown at drum pressure; equilibrium flash; no carry-over of liquid with the flash steam.
  • No heat loss from the vessel or cooler; the cooler is counter-flow when the make-up leaves hotter than the drain.
  • The flash steam is used where it condenses at the flash pressure (usually the deaerator).

References

  • IAPWS R7-97(2012) IF97

Questions and answers

How much heat can be recovered from blowdown?

With a flash vessel feeding the deaerator and a drain cooler, typically over 90 %. For 2 t/h at 45 bar(a), flashing at 2 bar(a) and cooling the drain to 35 °C against make-up at 30 °C, 545 kW of the 553 kW above make-up temperature is recovered.

Where does the flash steam go?

Usually into the deaerator at the flash vessel pressure, where it condenses and heats the feedwater. Its heat is counted above the make-up water temperature.

Why is the make-up temperature rise small?

The residual blowdown is a small flow cooled across a wide range, while the make-up flow is many times larger, so its temperature rises only a few kelvin.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.